Bodyport secures FDA 510(k) clearance for the Bodyport Cardiac Scale. LEARN MORE

Research & Press

September 26, 2024

Published Clinical Results Show Non-Invasive Monitoring Technology Predicts Heart Failure Events at Twice the Rate of Conventional Care

SAN FRANCISCO, September 26, 2024 /PRNewswire/ – The Journal of Cardiac Failure has published data from the SCALE-HF 1 study on Bodyport Inc.’s, non-invasive biomarker guided technology, showing it predicts heart failure events at twice the rate of weight-based monitoring, with an average lead time of 14 days and with 38% fewer false alerts. The results highlight the technology’s potential to reduce hospitalization risks for heart failure patients.

Participants in the study took measurements at home by standing barefoot for approximately 30 seconds a day on the Bodyport Cardiac Scale, a non-invasive device in the form factor of a weight scale but capturing multiple validated biomarker measures that directly reflect a patient’s fluid levels, the primary measure healthcare teams monitor to detect worsening heart failure.

“This is really exciting technology that I think has the potential to improve care for patients living with heart failure. This technology took a common tool that we have used in clinical care for decades, a bathroom scale, and improved it to the point that we can better predict worsening heart events,” said Adam DeVore, MD, MHS, cardiologist and associate professor of medicine at Duke University School of Medicine. “The data from this SCALE-HF 1 study suggest that we may be able to use this technology to prevent hospitalizations related to volume overload.” 

Key Study ResultsDetails
Study TypeProspective, observational (SCALE-HF 1)Congestion-related biomarkers analyzed by the Congestion Index
Participants329 enrolled at 8 sites56% of Patients LVEF ≤40% (reduced  ejection fraction)36% Patients LVEF ≥50% (preserved  ejection fraction)Follow up duration of 238 patient years
Heart Failure Event (HFE) Prediction
Congestion IndexCorrectly predicted 48 of 69 (70%) of heart failure events (HFEs) 
Weight-scale standardDetected 24 of 69 HFEs (35%)
SensitivityCongestion Index demonstrated significantly higher sensitivity (p<0.01) than weight-scale care
Congestion Index Alert RateGenerated 2.58 alerts per patient-year 
Weight-scale Alert RateProduced 4.18 alerts per patient-year
  • Fewer false alerts result in a more efficient workflow for care teams
  • Congestion Index is applicable across a broad range of heart failure patients (both reduced and preserved ejection fraction [EF])

“With twice the sensitivity of traditional weight-scale monitoring in Heart Failure, the Bodyport Congestion Index significantly outperforms the current noninvasive standard of care, yet captures hemodynamic data in a familiar scale form which is easy to adopt for patients,” said Corey Centen, founder, president, and chief technical officer at Bodyport.

The FDA-cleared Bodyport fluid management platform is currently being implemented in a variety of commercial settings to enhance heart failure care. By leveraging the Bodyport Cardiac Scale and Clinical Dashboard, healthcare organizations are developing fluid-guided care pathways aimed at improving patient outcomes and preventive care.

To access the SCALE-HF 1 data presented in the Journal of Cardiac Failure article, visit Surveillance and Alert-Based Multiparameter Monitoring to reduce Worsening Heart Failure Events: Results from SCALE-HF 1 – Journal of Cardiac Failure (onlinejcf.com).


To learn more about the Congestion Index and the FDA-cleared Cardiac Scale and commercial availability, visit www.bodyport.com.


About Bodyport

Bodyport is a biomarker-guided digital therapeutics company on a mission to address complex chronic conditions by embedding a sophisticated biomarker platform into simple, easy-to-use devices. Bodyport captures hemodynamic signals through the Cardiac Scale to power optimized interventions tailored to the patient. By not requiring a wearable device or surgical implant, the solution seamlessly integrates into a patient’s daily life.

Bodyport is focused on keeping patients with cardiorenal conditions healthier and out of the hospital. The company is tackling heart failure first to noninvasively assess heart function and fluid status in a single step at home. Bodyport is HIPAA compliant and has received SOC2 Type 2 certification.

Based in San Francisco, the company is backed by top-tier investors such as Boehringer Ingelheim Venture Fund, Playground Global, Initialized Capital, Y Combinator, and Rock Health.

For more information, visit bodyport.com and follow the company on LinkedIn and Twitter.

Bodyport Inc.
120 2nd Street, 2nd Floor
San Francisco, CA 

Subscribe to receive the latest news from Bodyport

This field is for validation purposes and should be left unchanged.

Bodyport is a Member of the American Heart Association’s Innovators’ Network

Copyright © 2024 Bodyport Inc. All Rights Reserved.